16 digital channels (as inputs or outputs), 24 Vdc, 0.5 A, inputs for sink wiring, outputs for source wiring, configurable input filter, M8 connection technology, high packaging density, LEDs to indicate the status
Digital mixed module 24 Vdc with 16 channels, configurable as input or output via software, 16x M8 3-pin with one channel per outlet
16 digital channels, configurable as input or output
Replacement of passive distributors
Adjustable digital input filters
The outputs are equipped with a single channel diagnostic
Extensive additional state information
In order to parameterize a module per PLC Configuration in the device editor, proceed as follows:
|
Step |
Action |
|---|---|
|
1 |
Append module in the beneath a Sercos III bus interface (TM5NS31). |
|
2 |
Afterwards double-click the module in the . Result: The device editor is opened and the tabs , , and are displayed. |
The input and output channels of the module are mapped to project variables that are used by the application.
|
Channel |
Meaning |
Default value |
Data type |
|---|---|---|---|
|
Digital input 00 Digital input 01 Digital input 02 Digital input 03 Digital input 04 Digital input 05 Digital input 06 Digital input 07 Digital input 08 |
– |
BYTE |
|
|
Digital inputs 9–16 |
Digital input 09 Digital input 10 Digital input 11 Digital input 12 Digital input 13 Digital input 14 Digital input 15 Digital input 16 |
– |
BYTE |
|
Digital output 00 Digital output 01 Digital output 02 Digital output 03 Digital output 04 Digital output 05 Digital output 06 Digital output 07 Digital output 08 |
– |
BYTE |
|
|
Digital outputs 9–16 |
Digital output 09 Digital output 10 Digital output 11 Digital output 12 Digital output 13 Digital output 14 Digital output 15 Digital output 16 |
– |
BYTE |
|
Diag In 1 |
– |
BYTE |
|
|
Diag In 2 |
Status of digital outputs 9–16 |
– |
BYTE |
A selection list (Direction0x) or a direct input (InputFilter) is used for setting the values.
The check box is used for switching between the numeric and the symbolic value.
|
Name |
Meaning |
Numeric/symbolic value |
Default value |
Data type |
|---|---|---|---|---|
|
Input filter |
0 / 0 |
0 / 0 |
BYTE |
|
|
Direction0x |
Configurable input and output |
Direction01: 1 / output Direction02: 2 / output Direction03: 4 / output Direction04: 8 / output Direction05: 16 / output Direction06: 32 / output Direction07: 64 / output Direction08: 128 / output Direction09: 1 / output Direction10: 2 / output Direction11: 4 / output Direction12: 8 / output Direction13: 16 / output Direction14: 32 / output Direction15: 64 / output Direction16: 128 / output |
0 / input |
BYTE |
For further information, see the TM7 digital I/O POUs hardware manual.