8563 Encoder error detected

Description

Refer to Diagnostic class (standard): 3

An error was detected in the position measuring system (encoder).

Cause

Solution

The encoder system is disturbed by external magnetic fields.

Remove the external sources of interference (magnetic fields) and restart the Multi carrier transport system.

Detected multi carrier hardware error: The encoder magnet of a carrier is inoperable.

Verify the encoder magnet of the carrier. Replace the encoder magnet or the carrier if necessary.

Detected multi carrier hardware error: The encoder system of a segment is inoperable.

Replace the multi carrier segment.