Display Mode

Overview

The Display mode view opens on the right-hand side when you select an axis (time or Y axis) in the Presentation (diagrams) tree view.

The parameters displayed depend on the axis that is selected:

Parameter

Description

Display mode

Select the following scaling options:

  • Auto

    If this option is selected, EcoStruxure Machine Expert scales the axis automatically.

  • Fixed length

    Only available for time axis: If this option is selected, EcoStruxure Machine Expert displays a segment of constant length.

  • Fixed

    If this option is selected, EcoStruxure Machine Expert displays a time or Y axis defined by the Minimum and Maximum parameters.

Minimum

When the Display mode > Fixed is selected, enter a start value for the axis. It can be a literal, variable (integer data type), or constant variable (integer data type).

Maximum

When the Display mode > Fixed is selected, enter an end value for the axis.

Length

Only available for a time axis when the Display mode > Fixed length is selected. Enter a value to define a constant length for the axis. The start value is adapted accordingly.

Grid

Select the option Grid to create a diagram with grid lines in x- or y-direction.

Select the color of the grid lines from the list next to the Grid parameter.

Description

Only available for Y axis. Select the option Description and enter a describing text in the box that will be displayed in the upper left corner of the diagram.

Tick marks section

Fixed spacing

If the option Fixed spacing is selected, EcoStruxure Machine Expert draws tick marks with Distance and Subdivisions.

Distance

Enter a value to define the distance between the tick marks.

Subdivisions

Enter a value to define the number of subdivisions between two tick marks.

The following elements are available:

Element

Description

Font button

Click the Font button to open the Font dialog box and configure the font for the selected axis.

Reset button

Click the Reset button to reset the settings to the default values.

Use as default button

Click the Use as default button to save the settings as default values.

Preview link

Click the Preview link to see a preview of the diagram you defined in the Display mode view.

If a trace is selected in the Trace Record tree view, the following elements are available:

Element

Description

Add variable link

Click the link to add a new trace variable to the Trace Record tree view.

Delete variable link

Click the Delete variable link to delete the selected trace variable from the Trace Record tree view.

Preview

The preview of the diagram you defined in the Display mode view is displayed when you click the Preview link in the Display mode view.

Underneath the preview of the diagram, the following elements are available:

Element

Description

Backcolor parameter

Select a color for the background of the diagram from the list next to the Backcolor parameter.

Backcolor on Selection parameter

Select a color for the background of the selected diagram from the list next to the Backcolor on selection parameter.

Add diagram link

If a diagram is selected, click the Add diagram link to add a new diagram to the Display mode view.

Delete diagram link

If a diagram is selected, click the Delete diagram link to delete the selected diagram from the Display mode view.

Reset display settings link

Click the Reset display settings link to reset the display settings of the selected diagram or the selected y-axis to the default values.

OK button

Click the OK button to confirm the configuration settings and to save the trace configuration.