There are two ways of proceeding for handling and mounting of the robot. Study both ways of proceeding and determine which one is appropriate for your environment.
| WARNING | |
|---|---|
| Step | Action | 
|---|---|
| 1 | Using a forklift truck, lift the robot and the pallet into the enclosure.   | 
| 2 | Fasten the robot to the frame using the six provided counterbores (1). Size of the counterbore: M12 Tightening torque: 56 Nm (496 lbf-in) Property class of the screws: 8.8 or greater, or A2-70 or greater   | 
| 3 | Remove the cross piece cartons, the base carton and the plastic pallet from the robot. | 
For information about the disposal of the packaging, refer to Disposal.
| WARNING | |
|---|---|
| Step | Action | 
|---|---|
| 1 | Pull two lifting lugs to the crane eyes at the mounting plate.   | 
| 2 | Use the crane to carefully lift the robot into the enclosure. | 
| 3 | Fasten the robot to the frame using the six provided counterbores (1). Size of the counterbore: M12 Tightening torque: 56 Nm (496 lbf-in) Property class of the screws: 8.8 or greater, or A2-70 or greater |