The use and application of the information contained herein require expertise in the design and programming of automated control systems. Only you, the user, machine builder or integrator, can be aware of all the conditions and factors present during installation and setup, operation, repair, and maintenance of the machine or process.
You must also consider any applicable standards and/or regulations with respect to grounding of all equipment. Verify compliance with any safety information, different electrical requirements, and normative standards that apply to your machine or process in the use of this equipment.
| DANGER | |
|---|---|
| WARNING | |
|---|---|
|
Step |
Action |
|---|---|
|
1 |
Remove the upper arm as described in Replacing the Upper Arms. |
|
2 |
|
|
3 |
Disconnect and remove the ground cable from the motor. |
|
4 |
Remove the 16 bolts (1) by means of which the gearbox is bolted to the mounting plate.
|
|
5 |
Carefully remove the motor and gearbox (5) from the mounting plate in rearward direction.
NOTE: Do not tilt transmission and do not damage the alignment hole at the mounting plate.
|
|
Step |
Action |
|---|---|
|
1 |
Remove the plug screw (2) on the gearbox flange.
|
|
2 |
Remove the four screws (3) on the motor which connect the motor to the gearbox. |
|
3 |
Carefully rotate the motor until the screw on the clamping flange appears in the aperture of the plug screw. |
|
4 |
Loosen the screw in the clamping flange. |
|
5 |
Carefully remove the motor from the gearbox. |
| NOTICE | |
|---|---|
|
Step |
Action |
|---|---|
|
1 |
Ensure that the gearbox and the housing are at the same temperature, as otherwise - in the case of a temperature difference - the gearbox may not fit into the aperture provided. |
|
2 |
Attach the motor to the gearbox according to the specifications of the manufacturer. Tightening torques for VRKT1:
Tightening torques for VRKT2, VRKT3, VRKT5:
|
|
3 |
Insert the plug screw into the gearbox flange. |
|
4 |
Attach the motor/gearbox combination to the robot mounting plate in the orientation specified. Tightening torque: 4.7 Nm (42 lbf-in) For further information, refer to the respective detail drawing in Mechanical and Electrical Data. |
| NOTICE | |
|---|---|
|
Step |
Action |
|---|---|
|
1 |
Attach the ground strap to the motor. Tightening torque: 2.9 Nm (25.7 lbf-in) For further information about motor assembly, observe the respective operating instructions of the motors:
|
|
2 |
Attach the motor supply cables and lock them in position. |
|
3 |
When using a new gearbox: Mount the threaded pin (1) as otherwise it may not be possible to mount the upper arm.
NOTE: Verify that the threaded pin protrudes approximately 3 mm (0.118 in)
For further information, refer to the respective detail drawing in Mechanical and Electrical Data. |
|
4 |
Mount the upper arm as described in Replacing the Upper Arms. |
|
5 |
|
|
6 |
Mount the lower arms with parallel plate to the upper arms and mount the parallel rods. For further information, refer to Mounting the Lower Arms with Parallel Plate and Mounting the Rods for Parallel Linkage. |
| NOTICE | |
|---|---|