The safety module eSM offers the following safety-related functions:
|
Safety-related sub-functions as per IEC 61800-5-2: |
|
|---|---|
|
STO |
Safe Torque Off No power that can cause torque or force is supplied to the motor. |
|
SOS |
Safe Operating Stop SOS monitors the standstill position. The power stage is enabled. |
|
SLS |
Safely Limited Speed SLS monitors speed limits. |
|
SS1 |
Safe Stop 1, type SS1-r (ramp-monitored) SS1 consists of:
|
|
SS2 |
Safe Stop 2 , type SS2-r (ramp-monitored) SS2 consists of:
|
The safety-related functions listed above correspond to the safety-related sub-functions as defined by IEC 61800-5-2. The term “safety-related function” in the present document corresponds to the term “safety-related sub-function” as defined by IEC 61800-5-2 for the above functions.