Type |
EF |
|
Offline editable |
No |
|
Devices supporting the parameter |
PacDrive LMC x00C, PacDrive LMC x01C, OnBoard I/O, DIO8 module |
|
Traceable |
Yes |
The parameter is used to enter a bit to enable or disable the diagnostic message 8788 Wiring error detected with ext. diagnostic message Openload for this digital field output.
This bit in the parameter OpenloadDiagMsg is assigned to a corresponding bit in the bitmask of the parameter OpenloadDiagMsk. Modifications in the parameter OpenloadDiagMsg are automatically written to the corresponding bit in the parameter OpenloadDiagMsk and vice-versa. The last modification is active. Also see parameter OverloadDiagMsg.
|
Value |
Data type |
Meaning |
|---|---|---|
|
L / 0 |
UINT |
The output does not report the diagnostic message |
|
H / 1 |
UINT |
The output reports the diagnostic message |