Keeping a stock of important components helps ensure the availability of your machine. Only exchange devices with identical types to help ensure compatibility.
Indicate the following information on the replacement equipment order, which can be found on the logistic type plate:
|
Parameter |
Example value |
Position on type plate |
|---|---|---|
|
Item name |
Robot P4l-R-NO-15-1200 |
First line |
|
Item reference (type code) |
VRKP4L0RNO00000 |
ID-No |
|
Hardware revision |
S00 |
HW |
When using the Lexium P robot in a production environment, consider keeping the following replacement equipment packages in stock:
|
Item reference |
Item name |
Quantity* |
||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
VRKP0 |
VRKP0•••••••E00 |
VRKP1 |
VRKP1•••••••E00 |
VRKP2 |
VRKP4 |
VRKP5 |
VRKP6 |
VRKP6•••••••E00 |
||
|
VRKP0YYYYY00002 |
Upper arm |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
VRKP1YYYYY00002 |
0 |
0 |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP2YYYYY00002 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
0 |
|
|
VRKP4YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
|
|
VRKP5YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
|
|
VRKP6YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
(1)** |
|
|
VRKP1YYYYY00003 |
Gearbox main axis |
(1)** |
(1)** |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
|
VRKP4YYYYY00003 |
0 |
0 |
0 |
0 |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
|
|
VRKP4YYYYY00006 |
Parallel plate with ball pins |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
|
VRKP4YYYYY00024 |
Ball pins - set of 12 |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
|
VRKP4YYYYY00025 |
Ball sockets - set of 12 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
VRKP4YYYYY00028 |
Fan |
0 |
0 |
0 |
0 |
(1)*** |
(1)*** |
(1)*** |
(1)*** |
(1)*** |
|
VRKP1YYYYY00032 |
Springs - set of 6 |
1 |
1 |
1 |
1 |
0 |
0 |
0 |
0 |
0 |
|
VRKPXYYYYY00032 |
0 |
0 |
0 |
0 |
1 |
1 |
1 |
1 |
1 |
|
|
VRKP0YYYYY00037 |
Lower arm pair |
1 (2)** |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
VRKP1YYYYY00037 |
0 |
1 (2)** |
1 (2)** |
0 |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP2YYYYY00037 |
0 |
0 |
0 |
1 (2)** |
1 (2)** |
0 |
0 |
0 |
0 |
|
|
VRKP4YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
0 |
0 |
|
|
VRKP5YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
0 |
|
|
VRKP6YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
|
|
VRKP6YYYYY00E37 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
|
|
* When using more than one robot, increase the amount accordingly. ** Only if there are increased requirements on the availability of the machine. *** Only for robots VRKP2•••WD / VRKP2•••WF / VRKP4L0•WD / VRKP4L0•NO / VRKP4S0•WF / VRKP5S0•WF / VRKP6S0•WF with increased requirements on the availability of the machine. |
||||||||||
When using the Lexium P robots in a production environment, consider keeping the following replacement equipment packages in stock:
|
Item reference |
Item name |
Quantity* |
||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
VRKP0 |
VRKP0•••••••E00 |
VRKP1 |
VRKP1•••••••E00 |
VRKP2 |
VRKP4 |
VRKP5 |
VRKP6 |
VRKP6•••••••E00 |
||
|
VRKP0YYYYY00002 |
Upper arm |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
VRKP1YYYYY00002 |
0 |
0 |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP2YYYYY00002 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
0 |
|
|
VRKP4YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
|
|
VRKP5YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
|
|
VRKP6YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
(1)** |
|
|
VRKP1YYYYY00003 |
Gearbox main axis |
(1)** |
(1)** |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
|
VRKP4YYYYY00003 |
0 |
0 |
0 |
0 |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
|
|
VRKP4YYYYY00029 |
Parallel plate with bearing and ball pins |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
|
VRKP4YYYYY00012 |
Slide films - three sets of three |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
VRKP4YYYYY00024 |
Ball pins - set of 12 |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
|
VRKP4YYYYY00025 |
Ball sockets - set of 12 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
VRKP4YYYYY00028 |
Fan |
0 |
0 |
0 |
0 |
(1)*** |
(1)*** |
(1)*** |
(1)*** |
(1)*** |
|
VRKP1YYYYY00032 |
Springs - set of 6 |
1 |
1 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
|
VRKPXYYYYY00032 |
0 |
0 |
0 |
1 |
1 |
1 |
1 |
1 |
1 |
|
|
VRKP0YYYYY00033 |
Telescopic axis |
(1)** |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
VRKP0YYYYY00E33 |
0 |
(1)** |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP1YYYYY00033 |
0 |
0 |
(1)** |
0 |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP1YYYYY00E33 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP2YYYYY00033 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
0 |
|
|
VRKP4YYYYY00033 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
|
|
VRKP5YYYYY00033 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
|
|
VRKP6YYYYY00033 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
|
|
VRKP6YYYYY00E33 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
|
|
VRKP0YYYYY00037 |
Lower arm pair |
1 (2)** |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
VRKP1YYYYY00037 |
0 |
1 (2)** |
1 (2)** |
0 |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP2YYYYY00037 |
0 |
0 |
0 |
1 (2)** |
1 (2)** |
0 |
0 |
0 |
0 |
|
|
VRKP4YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
0 |
0 |
|
|
VRKP5YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
0 |
|
|
VRKP6YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
|
|
VRKP6YYYYY00E37 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
|
|
VRKPXYYYYY00040 |
Plain bearing |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
VRKPXYYYYY00043 |
Upper universal joint |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
VRKPXYYYYY00044 |
Lower universal joint |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
* When using more than one robot, increase the quantity accordingly. ** Only if there are increased requirements on the availability of the machine. *** Only for robots VRKP2•••WD / VRKP2•••WF / VRKP4L0•WD / VRKP4L0•NO / VRKP4S0•WF / VRKP5S0•WF / VRKP6S0•WF with increased requirements on the availability of the machine. |
||||||||||
When using the Lexium P robots in a production environment, consider keeping the following replacement equipment packages in stock:
|
Item reference |
Item name |
Quantity* |
||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
VRKP0 |
VRKP0•••••••E00 |
VRKP1 |
VRKP1•••••••E00 |
VRKP2 |
VRKP4 |
VRKP5 |
VRKP6 |
VRKP6•••••••E00 |
||
|
VRKP0YYYYY00002 |
Upper arm |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
VRKP1YYYYY00002 |
0 |
0 |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP2YYYYY00002 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
0 |
|
|
VRKP4YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
|
|
VRKP5YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
|
|
VRKP6YYYYY00002 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
(1)** |
(1)** |
|
|
VRKP1YYYYY00003 |
Gearbox main axis |
(1)** |
(1)** |
(1)** |
(1)** |
0 |
0 |
0 |
0 |
0 |
|
VRKP4YYYYY00003 |
0 |
0 |
0 |
0 |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
|
|
VRKP4YYYYY00024 |
Ball pins - set of 12 |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
(1)** |
|
VRKP4YYYYY00025 |
Ball sockets - set of 12 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
|
VRKP4YYYYY00028 |
Fan |
0 |
0 |
0 |
0 |
(1)*** |
(1)*** |
(1)*** |
(1)*** |
(1)*** |
|
VRKP1YYYYY00032 |
Springs - set of 6 |
1 |
1 |
1 |
1 |
0 |
0 |
0 |
0 |
0 |
|
VRKPXYYYYY00032 |
0 |
0 |
0 |
0 |
1 |
1 |
1 |
1 |
1 |
|
|
VRKP0YYYYY00037 |
Lower arm pair |
1 (2)** |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
VRKP1YYYYY00037 |
0 |
1 (2)** |
1 (2)** |
0 |
0 |
0 |
0 |
0 |
0 |
|
|
VRKP2YYYYY00037 |
0 |
0 |
0 |
1 (2)** |
1 (2)** |
0 |
0 |
0 |
0 |
|
|
VRKP4YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
0 |
0 |
|
|
VRKP5YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
0 |
|
|
VRKP6YYYYY00037 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
0 |
|
|
VRKP6YYYYY00E37 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 (2)** |
|
|
VRKPXYYYYY00045 |
Rotational Module B |
0 |
0 |
0 |
0 |
0 |
(1)** |
0 |
0 |
0 |
|
* When using more than one robot, increase the amount accordingly. ** Only if there are increased requirements on the availability of the machine. *** Only for robots VRKP2•••WD / VRKP2•••WF / VRKP4L0•WD / VRKP4L0•NO / VRKP4S0•WF / VRKP5S0•WF / VRKP6S0•WF with increased requirements on the availability of the machine. |
||||||||||