64-Bit
From the May 2023 update of Geo SCADA Expert 2022 (85.8544.1) we have changed the minimum versions of Windows operating systems that Geo SCADA Expert supports. The minimum versions on which you can now install Geo SCADA Expert are Windows 10 (version 1607) or Windows Server 2016. Installation of Geo SCADA Expert on older operating systems is blocked.
Install Geo SCADA Expert server, Geo SCADA Mobile Server, or Virtual ViewX server software on computers that are using one of the following 64-bit operating systems:
Server Hardware
- Windows Server 2022 (Standard and Datacenter editions, 'Desktop Experience' installation option)
With Windows Server 2022, the above installation option is only offered during initial installation. Take care to select the correct installation option during that installation process.
- Windows Server 2019 (Standard and Datacenter editions, 'Desktop Experience' installation option)
With Windows Server 2019, the above installation option is only offered during initial installation. Take care to select the correct installation option during that installation process.
- Windows Server 2016 (Standard and Datacenter editions, 'Server with Desktop Experience' installation option).
With Windows Server 2016, the above installation option is only offered during initial installation. Take care to select the correct installation option during that installation process.
When you install Virtual ViewX server on a machine, ViewX is installed on that server. Whenever you connect to that server, ViewX runs on that server machine. As such, that instance of ViewX will make use of the graphical capabilities of that server machine, sharing the load with the CPU.
Desktop Hardware
For server installations, desktop class hardware is only suitable for small stand-alone Geo SCADA Expert client-server systems that are not intended to provide access to the database from either Virtual ViewX or Geo SCADA Mobile.
Use desktop class hardware for client computers, such as those that are running either ViewX, Virtual ViewX, Original WebX, or Data Access software.
The following operating systems are supported:
- Windows 11 (Professional and Enterprise editions, versions that are supported by Microsoft)
(Geo SCADA Expert is tested against the latest version of Windows 11 at the point of its release.) - Windows 10 (version 1607 onwards) (Professional and Enterprise editions, versions that are supported by Microsoft).
(Version 1607 is also known as the 'Windows 10 Anniversary Update'.)
(Geo SCADA Expert is tested against the latest version of Windows 10 at the point of its release.)
ATTENTION: Desktop versions of Windows should not be used for servers with more than two clients. This is for performance reasons.
If you intend to provide access to the database from Geo SCADA Mobile, install the server software on server class computers with 64-bit operating systems.
Likewise, to run Virtual ViewX, the Virtual ViewX server and Geo SCADA Expert server computers have to run on server class hardware with 64-bit operating systems. (Virtual ViewX client computers also have to use 64-bit operating systems. The Virtual ViewX client computers also require an HTML-5 compatible web browser (see Web Browser Support ).)
(To run only the Original WebX client, client computers require Microsoft Edge in Internet Explorer mode. Other browsers are not supported.)