Define whether Geo SCADA Expert reports 1-Jan-1601 00:00:00 as Null

In Geo SCADA Expert, the default date and time value for items that have not yet had their date and time value set is 1-Jan-1601 00:00:00. For example, a new database point that has not had its date and time set will have a date and time value of 1-Jan-1601 00:00:00.

Some ODBC clients do not support dates as far back as 1-Jan-1601 00:00:00. For example, SQL Server 2005 does not support time stamps as far back as 1-Jan-1601 00:00:00, and so it experiences problems if the Geo SCADA Expert contains items with the default date and time setting. By using the Return 1-Jan-1601 as NULL check box, you can avoid such problems—you can set Geo SCADA Expert to report 1-Jan-1601 00:00:00 as null. The null value can be recognized by those ODBC clients that do not support the default 1-Jan-1601 00:00:00 date and time value.

To define whether Geo SCADA Expert reports 1-Jan-1601 00:00:00 as null, you need to display the ODBC Setup window Configure the ODBC DSN Settings, then use the Return 1-Jan-1601 as NULL check box: