Interruptions
|
PQ Performance Diagrams PQ Rating Gadget PQ Rating Trend Gadget PQ Incident Breakdown Gadget PQ Incident Impact Gadget PQ Incident Location Gadget PQ Analysis Report PQ Impact Gadget PQ Impact Trend Gadget PQ Impact Report
|
ION 7350, 7400, 7550, 7650, 8600A, 8600B, 8650A, 8650B, 8650C, 8800A, 8800B, 8800C, 9000, PM8000, PM870, CM3350, CM4000, PM5650, PM5760, PM5761
DDD Support: ION7400, ION7550 V350 and newer, ION7650 V350 and newer, ION8650A/B V4.20 and newer, ION9000, PM8000, CM4000
|
All default meter template
|
Voltage Sag
|
Same as Interruptions
|
Same as Interruptions
|
All default meter template
|
Voltage Swell
|
Same as Interruptions
|
Same as Interruptions
|
All default meter template
|
Transient Voltage
|
Same as Interruptions
|
ION 7650, 8600A, 8650A, 8650B, 8800A, 9000, CM4000T, PM5650, PM5760, PM5761
DDD Support: ION7650 V350 and newer, ION8650A/B V4.20 and newer, ION9000, CM4000T
|
All default meter template
|
Over Voltage
|
Same as Interruptions
|
ION 7350, 7400, 7550, 7650, 8600A, 8600B, 8650A, 8650B, 8650C, 8800A, 8800B, 8800C, 9000, PM8000, PM5650, PM5760, PM5761
|
All default meter template
|
Under Voltage
|
Same as Interruptions
|
ION 7350, 7400, 7550, 7650, 8600A, 8600B, 8650A, 8650B, 8650C, 8800A, 8800B, 8800C, 9000, PM8000, PM5650, PM5760, PM5761
|
All default meter template
|
Voltage Unbalance
|
PQ Performance Diagrams PQ Rating Gadget PQ Rating Trend Gadget PQ Analysis Report
|
Logged By Default: ION 7330, 7350, 7400, 7550, 7650, 8600A, 8600B, 8650A, 8650B, 8800A, 8800B, 9000, PM8000, CM3000, CM4000, TesysT, Micrologic 5.0/6.0/7.0 E/P/H (including IFE/IFM), PM5650, PM5760, PM5761 Not Logged By Default: PM8001, PM3250, PM3255, PM5100, PM5300, PM5350, PM5500, EM6400, EM7000, Micrologic 5.2/6.2/5.3/6.3 E
|
All default meter template
|
Current Unbalance
|
PQ Performance Diagrams PQ Rating Gadget PQ Rating Trend Gadget PQ Analysis Report
|
Logged By Default: TesysT, Micrologic 5.0/6.0/7.0 E/P/H (including IFE/IFM), PM5650, PM5760, PM5761 Not Logged By Default: PM8001, CM3000, CM4000, PM3250, PM3255, PM5100, PM5300, PM5350, PM5500, EM6400, EM7000, Micrologic 5.2/6.2/5.3/6.3 A/E
|
n/a
|
Voltage Harmonics
|
PQ Performance Diagrams PQ Rating Gadget PQ Rating Trend Gadget PQ Analysis Report
|
Logged By Default: ION 7330, 7350, 7400, 7550, 7650, 8600A, 8600B, 8650A, 8650B, 8800A, 8800B, 9000, PM8000, CM3000, CM4000, PM5650, PM5760, PM5761 Not Logged By Default: ION 6200, 7300, 8600C, 8650C, 8800C, PM200, PM700, PM8001, PM1200, PM3250, PM3255, PM5100, PM5300, PM5350, PM5500, EM3460, EM6400, EM7000, Micrologic 5.2/6.2/5.3/6.3 E, Micrologic 5.0/6.0/7.0 H (including IFE/IFM)
|
All default meter template except PM8000 with IEEE 519 template
|
Current Harmonics
|
PQ Performance Diagrams PQ Analysis Report
|
Logged By Default: ION 7330, 7350, 7400, 7550, 7650, 8600A, 8600B, 8650A, 8650B, 8800A, 8800B, 9000, PM8000, CM3000, CM4000, PM5650, PM5760, PM5761 Not Logged By Default: ION 6200, 7300, 8600C, 8650C, 8800C, PM200, PM700, PM8001, PM1200, PM3250, PM3255, PM5100, PM5300, PM5350, PM5500, EM3460, EM6400, EM7000, Micrologic 5.2/6.2/5.3/6.3 E, Micrologic 5.0/6.0/7.0 H (including IFE/IFM)
|
All default meter template except PM8000 with IEEE 519 template
|
Frequency Variation
|
PQ Performance Diagrams PQ Rating Gadget PQ Rating Trend Gadget PQ Analysis Report
|
Logged By Default: ION 7330, 7350, 7400, 7550, 7650, 8600A, 8600B, 8650A, 8650B, 8800A, 8800B, 9000, PM8000, PM5650, PM5760, PM5761
|
All default meter template
|
Flicker
|
PQ Performance Diagrams PQ Rating Gadget PQ Rating Trend Gadget PQ Analysis Report
|
Logged By Default: ION 7400, 7650, 8600A, 8650A, 8800A, 8800B, 9000, PM5650, PM5760, PM5761
|
PQ Framework and EN50160 evaluation enabled
|
Power Factor
|
Power Factor Impact Gadget Power Factor Impact Trend Gadget |
All meters that have measurements required by the calculation of the defined rate structure.
For example:
- Active energy
- Reactive energy
- Active power
- Reactive power
|
n/a |
PQ Analysis Report |
All meters that measures active energy, reactive energy, and power factor |
n/a |
n/a |
Standardized Equipment Diagrams |
Uninterruptible Power Supplies (UPS) |
|
Active Harmonic Filters |
Accusine PCS+ |
Accusine PFV+ |
|
Capacitor Banks |
VarPlus Logic VL6 and VL12 |
|
|
n/a |