Refer to Diagnostic class (standard): 3
|
Default reaction |
||
|---|---|---|
|
D |
E |
|
|
- |
- |
A module error is detected.
|
Ext. diagnosis |
Meaning |
|---|---|
|
Com. Com. IOModule |
A loss of communication is detected between DIO8 module (optional module of Lexium 62 ILM Module) and Lexium 62 ILM Module. Contact your Schneider Electric representative. |
|
DIVCLK |
An error is detected while synchronizing with the Sercos cycle. Contact your Schneider Electric representative. |
|
drive disabled |
The Lexium 62 ILM Module, on which the DIO8 module (optional module of the Lexium 62 ILM Module) was configured is deactivated and the DIO8 module is activated (Enable = TRUE). Verify and correct if necessary the PLC configuration. |
|
int. error |
Contact your Schneider Electric representative. |
NOTE: In certain cases, another diagnostic code or diagnostic class is entered in the message logger of the controller for DIO8 module and Lexium 62 ILM/Lexium 52 Drive onboard I/O modules in the message logger of the drive.