8827 Controller power-off/hardware monitor
Refer to Diagnostic class (standard): 3
MsgFilter: Bit 1 Diagnosis Messages
The hardware provides an internal error logger that logs the causes for error-dependent controller deactivations. The next time the controller is started, the error logger is analyzed, and the cause of the error can be given in the message logger. In addition, a more specific message is indicated (8055 Controller message HW monitor) that can be enabled by the MsgFilter parameter and activated via the Logic Builder message logger. This message is intended to be a debug message and provides the cause of the deactivation.
Cause |
Solution |
---|---|
DiagExtMsg defines the detected error in further detail (high or low voltage, high or low temperature, fan error, temperature sensor error): oVoltage<Min oVoltage>Max oTemp<Min oTemp>Max oFan error oLM75 error |
Contact your Schneider Electric representative. |