FB_ExceptionHandler - General Information

Overview

Type:

Function block

Available as of:

V1.0.4.0

Inherits from:

-

Implements:

-

Task

Distribution of reactions to subordinate modules.

Description

The POU can be activated using the i_xEnable input. Whether or not the POU is active can be seen at the q_xActive output. When the POU is activated, the input parameters are checked. If i_pstSubModulesItf, i_petReactionTranslationMode, i_pstReactionTransla­tionTable or i_pstReactionTranslationJobs is smaller or equal zero or if the specification in i_diNumberOfSubModules does not correspond to the i_udiSizeOfSubModulesItf variable, an exception is entered into the global exception list and the diagnostic outputs are set accordingly. The information from the i_udiModuleId and i_udiModuleName inputs is also entered into the exception data.

 As a local ExceptionHandler, the POU distributes the reactions that come from the i_stReaction input to the submodules. For every reaction and every submodule, it must decide which reaction(s) should occur on each individual submodule. The user can influence the reaction distribution by using the i_pstReactionTranslationTable or i_pstReactionTransla­tionJobs. If the i_xLocalExceptionHandler input is FALSE, the POU works as global ExceptionHandler. All reactions pending due to the exceptions are collected and, on the influence of the reaction translation table or reaction translation jobs, distributed to the submodules.

The available modes for translating the reactions are explained in the ET_ReactionTransla­tionMode enumeration type.

Using translation modes contains examples for use.

The q_diSubModuleInException output displays the subordinate module where an exception is pending. If several submodules show an exception, the first module with an exception is displayed. This function does not depend on whether the ExceptionHandler operates as a local or global POU.

When diagnostic messages are acknowledged (AutoQuit or i_xDiagQuit), their reactions to the submodules are deleted if no other exception causes the same reaction(s).

In the case of a global ExceptionHandler the FC_DiagQuit system function is called when system diagnostic messages are acknowledged and the global exception list is deleted. An entry into the global log data list is also generated to note the global acknowledgment in the log data list.

Interface

Input

Data type

Description

i_xEnable

BOOL

A rising edge FALSE -> TRUE activates the POU, a falling edge TRUE -> FALSE deactivates the POU.

A deactivated POU does not execute any actions.

i_xDiagQuit

BOOL

A rising edge FALSE -> TRUE acknowledges pending system/diagnostic messages.

i_stReaction

ST_Reaction

 

i_udiModuleId

UDINT

ID of the module in which the ExceptionHandler is called up.

i_sModuleName

STRING[80]

Name of the module in which the ExceptionHandler is called up.

i_pstSubModulesItf

POINTER TO ST_StandardModuleInterface

Pointer onto the array of ST_StandardModuleInterface of the submodules of the node.

i_udiSizeOfSubModulesItf

UDINT

Size in bytes of the structure ST_StandardModuleInterface

i_udiNumberOfSubModules

UDINT

Number of submodules of the node.

i_petReactionTranslationMode

POINTER TO ET_ReactionTranslationMode

Pointer onto the array of ET_ReactionTranslationMode that defines which reaction translation mode shall be used for which submodule of the node.

i_pstReactionTranslationTable

POINTER TO ST_Reaction

Pointer onto the two-dimensional array of ST_Reaction, which configures the reaction translation of the ET_ReactionTranslationMode.Table mode.

i_pstReactionTranslationJobs

POINTER TO ST_ReactionTranslationJobs

Pointer onto the array of ST_ReactionTranslationJobs, which configures the reaction translation of the ET_ReactionTranslationMode.Jobs mode.

i_xLocalExceptionHandler

BOOL

TRUE: The function block works as local ExceptionHandler

Output

Data type

Description

q_xActive

BOOL

TRUE: The POU is active and has to be executed further.

FALSE: The POU is inactive.

q_xReady

BOOL

TRUE: The POU is ready to operate and accepts user commands.

FALSE: the POU is not ready to operate and does not accept user commands.

q_etDiag

GD.ET_Diag

General, library-independent statement on the diagnostic.

A value unequal GD.ET_Diag.Ok equates an error message.

q_etDiagExt

ET_DiagExt

POU-specific output on the diagnostic.

q_etDiag = GD.ET_Diag.Ok -> status message

q_etDiag <> GD.ET_Diag.Ok -> diagnostic message

q_sMsg

STRING[80]

Event-triggered message which gives more detailed information on the diagnostic state.

q_udiSubModuleInException

UDINT

TRUE: One of the submodules of the node reports an exception.

Input/Output

Data type

Description

iq_stExceptionList

ST_ExceptionList

Global exception list

iq_stLogDataList

ST_LogDataList

Global log data list

Diagnostic Messages

q_etDiag

q_etDiagExt

Enumeration value

Description

OK

Disabled

22

Diagnostic message disabled

OK

Initializing

37

Initialization

OK

Working

47

The POU processes the function

ControllerConditionInvalid

ControllerInvalid

6

The controller is invalid.

InputParameterInvalid

PointerReactionTranslationJobsInvalid

144

The pointer ReactionTranslationJobs is invalid

InputParameterInvalid

PointerReactionTranslationModeInvalid

146

The pointer ReactionTranslationMode is invalid

InputParameterInvalid

PointerReactionTranslationTableInvalid

139

The pointer ReactionTranslationTable is invalid

InputParameterInvalid

PointerSubModulesItfInvalid

97

The pointer SubModulesItf is invalid

InputParameterInvalid

ReactionTranslationEntryInvalid

141

An entry of a reaction transfer is invalid

InputParameterInvalid

SizeOfSubModulesItfInvalid

96

The size of the submodule interface is invalid

UnexpectedProgramBehavior

InitExceptionListFailed

46

Initialization of the exception list failed.

ControllerInvalid

Enumeration name:

ControllerInvalid

Enumeration value:

6

Description:

The controller is invalid.

Issue

Cause

Solution

-

The controller does not provide the required conditions.

For more details, refer to the q_sMsg output.

Disabled

Enumeration name:

Disabled

Enumeration value:

22

Description:

Diagnostic message disabled

The function block is deactivated, it executes no actions whatsoever. i_xEnable and q_xActive have the value FALSE.

InitExceptionListFailed

Enumeration name:

InitExceptionListFailed

Enumeration value:

46

Description:

Initialization of the exception list failed.

Issue

Cause

Solution

-

Initialization of the exception list failed. - An internal execution error occured.

Try to initialize the exception list using the FC_InitExceptionList function.

Please inform the support team about this error.

Initializing

Enumeration name:

Initializing

Enumeration value:

37

Description:

Initialization

The function block is bein initialized and thus is not yet ready to receive commands at its inputs. The function block will signalize that it is ready for operation with the signal q_xReady = TRUE.

PointerReactionTranslationJobsInvalid

Enumeration name:

PointerReactionTranslationJobsInvalid

Enumeration value:

144

Description:

The pointer ReactionTranslationJobs is invalid

Issue

Cause

Solution

-

An invalid value has been applied at the input i_pstReactionTranslationJobs.

A valid memory address unequal 0 has to be transferred to the i_pstReactionTranslationJobs input.

PointerReactionTranslationModeInvalid

Enumeration name:

PointerReactionTranslationModeInvalid

Enumeration value:

146

Description:

The pointer ReactionTranslationMode is invalid

Issue

Cause

Solution

-

An invalid value was applied at the i_petReactionTranslationMode input.

A valid memory address unequal 0 has to be transferred to the i_petReactionTranslationMode input.

PointerReactionTranslationTableInvalid

Enumeration name:

PointerReactionTranslationTableInvalid

Enumeration value:

139

Description:

The pointer ReactionTranslationTable is invalid

Issue

Cause

Solution

-

At the input i_pstReactionTranslationTable an invalid value has been applied.

A valid memory address unequal 0 has to be transferred to the i_pstReactionTranslationTable input.

PointerSubModulesItfInvalid

Enumeration name:

PointerSubModulesItfInvalid

Enumeration value:

97

Description:

The pointer SubModulesItf is invalid

Issue

Cause

Solution

-

An invalid value was applied at the i_pstSubModulesItf input.

A valid memory address unequal 0 has to be transferred to the i_pstSubModulesItf input.

ReactionTranslationEntryInvalid

Enumeration name:

ReactionTranslationEntryInvalid

Enumeration value:

141

Description:

An entry of a reaction transfer is invalid

Issue

Cause

Solution

-

A reaction translation job of the ET_ReactionTranslationMode.Jobs translation mode is invalid.

The following must apply for a translation job:

oudiSourceStart >= 1

oudiNumReactions >= 1

oudiSourceStart + udiNumReactions - 1 <= Gc_udiMaxNumberOfReactions

oudiTargetStart + udiNumReactions - 1 <= Gc_udiMaxNumberOfReactions

SizeOfSubModulesItfInvalid

Enumeration name:

SizeOfSubModulesItfInvalid

Enumeration value:

96

Description:

The size of the submodule interface is invalid

Issue

Cause

Solution

-

The value of the i_udiSizeOfSubModulesItf input is invalid.

The specification at the i_diNumberOfSubModules input does not correspond to the specification at the i_udiSizeOfSubModulesItf input.

Working

Enumeration name:

Working

Enumeration value:

47

Description:

The POU processes the function

The function block distributes reactions to subordinate modules.

Methods

Name

Description

RegisterLoggerPoint

Registering the logger point of the POU in the Application Logger

SetException

Entering an exception into a global exception list