Replacement Equipment and Accessories Inventory
Keeping a stock of important components helps ensure the availability of your machine. Only replace the equipment and the accessories of the axis with identical types to help ensure compatibility.
Indicate the following information on the replacement equipment order, which can be found on the logistic type plate:
Parameter |
Example value |
Position on type plate |
---|---|---|
Axis type |
CAR42BCM0150A1NR / 2 1G 9 H5 9 |
First line |
Identification number |
0073000016016 |
Id.No. |
Serial number |
2700410441 |
Ser.No. |
Replacement Equipment and Accessories Stock for
When using the axis in a production environment, consider keeping the following replacement equipment packages in stock:
Replacement equipment |
Order number |
Quantity for axis |
||||
---|---|---|---|---|---|---|
CAR40 |
CAR41 |
CAR42 |
CAR43 |
CAR44 |
||
Sensor (optional equipment) |
(1) |
1 |
1 |
1 |
1 |
1 |
Expanding hub (optional equipment) |
SPM3MFSC10A14 |
1 |
1 |
0 |
0 |
0 |
SPM3MFSC20A20 |
0 |
0 |
1 |
1 |
1 |
|
Elastomer spider (optional equipment) |
SPM3MFR09A018 |
1 |
1 |
0 |
0 |
0 |
SPM3MFR14A034 |
0 |
0 |
1 |
1 |
1 |
|
Clamping hub (optional equipment) |
(2) |
1 |
1 |
1 |
1 |
1 |
Toothed belt |
(3) |
0 |
1 |
1 |
1 |
1 |
(1) Depending on the contact. Refer to Sensors for the appropriate order number. (2) Depending on the axis type. Refer to Clamping Hubs for the appropriate order number and to the corresponding motor or gearbox manual for the proper diameter (ØD). (3) Depending on the axis type and the characteristic feature. For the appropriate order number, refer to Toothed Belt. |
NOTE: If there is an increased requirement on the availability of the axis, keep also an appropriate motor and/or gearbox in stock.