Lexium 62 ILM Integrated Servo Drive
Product |
Description |
---|---|
![]()
|
The Lexium 62 ILM combines motor, power stage, and digital servo controller for an axis in a space-saving housing. Due to its compact design with the integrated drive, it is suitable for decentralized, distributed architectures. It is available with single-turn or multi-turn encoders, and simplifies configuration with the aid of the electronic nameplate in the Lexium 62 ILM. For further information, refer to: oIndicators of the Lexium 62 ILM Integrated Servo Drive oElectrical Connections for the Lexium 62 ILM Integrated Servo Drive oMechanical and Electrical Data for the Lexium 62 ILM Integrated Servo Drive |
The Lexium 62 ILMs are available in three different flange sizes:
oILM070 (70 mm / 2.76 in.)
oILM100 (100 mm / 3.94 in.)
oILM140 (140 mm / 5.51 in.)
The Lexium 62 ILMs have been derived from the Schneider Electric SH3 family of motors, and therefore share many characteristics. For instance, when it comes to mounting the motor, the Lexium 62 ILMs are equivalent.
The highlights:
oCompact design
o3.5 times peak torque
oIntegrated Sercos interface
oHigh-resolution single or multi-turn encoder
oDegree of protection IP65 (depending on the reference and/or options)
Device |
Reference |
---|---|
Lexium 62 ILM Integrated Servo Drive |
oILM0701P oILM0702P oILM0703P oILM1001P oILM1002P oILM1003P oILM1401P oILM1401M oILM1402P |
Item |
Meaning |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|
Product family |
ILM = Integrated Lexium Servo Module |
|||||||||
Flange size |
|
070 = 70 mm / 2.76 in. 100 = 100 mm / 3.94 in. 140 = 140 mm / 5.51 in. |
||||||||
Number of stacks |
|
1 = 1 Stack 2 = 2 Stacks 3 = 3 Stacks |
||||||||
Winding type |
|
P = Standard M = Optimized in terms of torque (available only with ILM1401) |
||||||||
|
0 = Smooth shaft, without shaft seal 1 = Parallel key, without shaft seal 2 = Smooth shaft, with shaft seal, IP65 3 = Parallel key, with shaft seal, IP65 |
|||||||||
|
1 = Absolute single-turn 128 SinCos periods per revolution 2 = Absolute multi-turn 128 SinCos periods per revolution |
|||||||||
|
A = Without holding brake F = With holding brake |
|||||||||
Variants |
|
0 |
||||||||
Internal |
|
0 = Standard production |
||||||||
Costumer |
|
|
00 = Standard |
|||||||
Type code (example) |
ILM |
070 |
1 |
P |
0 |
1 |
A |
0 |
0 |
00 |
Label |
Meaning |
---|---|
ILMxxxxxxxxxxxx |
Device type, see type code |
SN |
Serial number |
Input 1 |
Rated voltage and rated current of the power supply |
Input 2 |
Rated voltage and rated current of the electronics |
Type rating |
Degree of protection of the housing in accordance with NEMA 250 and UL 50. |
HW |
Hardware version |
SW |
Software version |
IPxx |
|
Th-Cl |
Insulation material class of the motor |
M0 |
Standstill torque |
Mmax |
Peak torque |
nN |
Nominal speed of rotation |
Date of manufacture |
|
Symbols |
This field displays the symbols of declarations and certifications. |