Replacing the Lower Arms

Replacing the Lower Arms

Step

Action

1

Grip one lower arm as close as possible to the ball socket and, for removal, pull the lower arm off the ball pin against the force of the spring.

2

Pull off the opposite arm from the ball pin.

3

Repeat the above steps for all lower arms.

4

Mount the new lower arms.

NOTICE

INOPERABLE EQUIPMENT

oFor removing the lower arms, hold tight the parallel plate as this parallel plate may move as a result of the removal of one arm.

oNever grip lower arms in their center as otherwise the arms are bent during extension and must be replaced.

Failure to follow these instructions can result in equipment damage.