Maintaining the Gearbox (Optional Equipment)
Step |
Action |
---|---|
1 |
Verify the gearbox by visual inspection for leakages and deposits of dirt on the gearbox output shaft sealing periodically in accordance with the maintenance schedule. |
2 |
Carefully remove deposits. Use lint-free cloths to clean the gearbox. NOTE: In case of a leakage, contact your local Schneider Electric service representative. |
NOTICE |
DAMAGED GEARBOXES DUE TO INAPPROPRIATE CLEANING OF THE GEARBOX |
oUse lint-free cloth for cleaning. oDo not clean dry deposits using compressed air. oDo not use solvents; for example, trichloroethylene, tetrachloromethane, or hydrocarbons nor sharp-edged objects, emery cloth, or emery paper. oMinimize the mechanical impacts when cleaning. |
Failure to follow these instructions can result in equipment damage. |