ST_VelFeedForwardFeedback - General Information
Type: |
data structure |
Available as of: |
V1.0.0.0 |
Inherits from: |
- |
Versions: |
Current version |
The structure contains the return values of the FB_MasterVelFeedForward POU.
Variable |
Data type |
Description |
---|---|---|
lrPartsPerMinuteInfeed |
LREAL |
The measured number of products which are accepted per minute by the feed belt specified with udiBeltId. |
lrTargetsPerMinuteOutfeed |
LREAL |
The measured number of targets that change to the last belt per minute |
lrFeedForwardOutfeed |
LREAL |
The calculated velocity at which the target belt has to move so that lrPartsPerMinuteInfeed is equal to lrTargetsPerMinuteOutfeed |
lrFeedForwardInfeed |
LREAL |
The calculated velocity at which the belt specified by udiBeltId has to move so that lrPartsPerMinuteInfeed is equal to lrTargetsPerMinuteOutfeed |