ST_VelFeedForwardParameter

 

ST_VelFeedForwardParameter - General Information

Overview

Type:

data structure

Available as of:

V1.0.0.0

Inherits from:

-

Versions:

Current version

Description

The structure contains the parameters of the FB_MasterVelFeedForward POU.

Structure Elements

Variable

Data type

Description

udiBeltId

UDINT

The number of the feed belt from which the accepted products per minute are to be determined

timAverageTime

TIME

The period of time over which the measured values for lrPartsPerMinuteInfeed and lrTargetsPerMinuteOutfeed are to be averaged

timRefreshTime

TIME

The interval at which the values for lrPartsPerMinuteInfeed and lrTargetsPerMinuteOutfeed are to be updated

lrAverageProductDistAtStart

LREAL

The mean product distance that is to be assumed as long as no measured values are available after the start

lrAverageTargetDistAtStart

LREAL

The mean target difference that is to be assumed as long as no measured values are available after the start