Adjusting Parameters

Overview

The list of parameters described in the table can be read or modified by using the EXPERTGetParam or EXPERTSetParam function blocks.

NOTE: Parameters set via the program override the parameters values configured in the HSC configuration window. Initial configuration parameters are restored on a cold or warm start.

Adjustable Parameters

This table provides the list of parameters from the EXPERT_PARAMETER_TYPE that can be read or modified while the program is running:

Parameter

Description

EXPERT_MODULO

to get or set the Modulo value of an HSC

EXPERT_THRESHOLD0

to get or set the Threshold 0 value of an HSC

EXPERT_THRESHOLD1

to get or set the Threshold 1 value of an HSC

EXPERT_THRESHOLD2

to get or set the Threshold 2 value of an HSC

EXPERT_THRESHOLD3

to get or set the Threshold 3 value of an HSC

EXPERT_REFLEX0

to get or set output 0 reflex mode of an EXPERT function

EXPERT_REFLEX1

to get or set output 1 reflex mode of an EXPERT function