The feedback interface provides status values for the configured parameters for a carrier.
|
Property |
Data type |
Accessing |
Description |
|---|---|---|---|
|
lrFrontOffset |
LREAL |
Read |
Indicates the distance from the center point of the carrier to the front edge of the complete unit consisting of carrier, tool and product. The calculated distance depends on the ToolDimensions and the ToolOffset as well as the ProductDimensions and the ProductOffset. For illustration, refer to the Front offset example. |
|
lrRearOffset |
LREAL |
Read |
Indicates the distance from the center point of the carrier to the rear edge of the complete unit consisting of carrier, tool and product. The calculated distance depends on the ToolDimensions and the ToolOffset as well as the ProductDimensions and the ProductOffset. For illustration, refer to the Rear offset example. |
|
rstCarrierDimensions |
REFERENCE TO ST_Dimensions |
Read |
Indicates the dimensions of the carrier. |
|
rstProductDimensions |
REFERENCE TO ST_Dimensions |
Read |
Indicates the dimensions of the configured product. |
|
rstProductOffset |
REFERENCE TO PDL.ST_Vector3D |
Read |
Indicates the specified center point of the product in relation to the center point of the carrier. For more information, refer to the method SetProductOffset. |
|
rstToolDimensions |
REFERENCE TO ST_Dimensions |
Read |
Indicates the dimensions of the configured tool. |
|
rstToolOffset |
REFERENCE TO PDL.ST_Vector3D |
Read |
Indicates the specified center point of the tool in relation to the center point of the carrier. For more information, refer to the method SetToolOffset. |
|
rstToolPivotPointOffset |
REFERENCE TO PDL.ST_Vector3D |
Read |
Indicates the specified ToolPivotPoint in relation to the center point of the carrier. For more information, refer to the method SetToolPivotPointOffset. |
|
xApplicationLoggerEntriesActive |
BOOL |
Read |
Indicates TRUE if the carrier writes messages to the . |
|
xProductPresent |
BOOL |
Read |
Indicates TRUE if a product is present on the carrier. |
|
xToolPresent |
BOOL |
Read |
Indicates TRUE if a tool is present on the carrier. |
Conditions:
Moving direction of the carrier: from left to right (clockwise)
Center point of the carrier: red crossing lines
Tool: blue box
Product: green box
Result:
FrontOffset: Distance from the center point of the carrier to the front edge of the complete unit consisting of carrier, tool and product
Conditions:
Moving direction of the carrier: from left to right (clockwise)
Center point of the carrier: red crossing lines
Tool: blue box
Product: green box
Result:
RearOffset: Distance from the center point of the carrier to the rear edge of the complete unit consisting of carrier, tool and product