Replacement Equipment Inventory

Overview

Keeping a stock of important components helps ensure the availability of your machine. Only exchange devices with identical types to help ensure compatibility.

Indicate the following information on the replacement equipment order, which can be found on the logistic type plate:

Parameter

Example value

Position on type plate

Item name

Robot P4l-R-NO-15-1200

First line

Item reference (type code)

VRKP4L0RNO00000

ID-No

Hardware revision

S00

HW

Replacement Equipment Stock for Robots without a Rotational Axis

When using the Lexium P robot in a production environment, consider keeping the following replacement equipment packages in stock:

Item reference

Item name

Quantity*

VRKP0

VRKP0•••••••E00

VRKP1

VRKP1•••••••E00

VRKP2

VRKP4

VRKP5

VRKP6

VRKP6•••••••E00

VRKP0YYYYY00002

Upper arm

(1)**

(1)**

0

0

0

0

0

0

0

VRKP1YYYYY00002

0

0

(1)**

(1)**

0

0

0

0

0

VRKP2YYYYY00002

0

0

0

0

(1)**

0

0

0

0

VRKP4YYYYY00002

0

0

0

0

0

(1)**

0

0

0

VRKP5YYYYY00002

0

0

0

0

0

0

(1)**

0

0

VRKP6YYYYY00002

0

0

0

0

0

0

0

(1)**

(1)**

VRKP1YYYYY00003

Gearbox main axis

(1)**

(1)**

(1)**

(1)**

0

0

0

0

0

VRKP4YYYYY00003

0

0

0

0

(1)**

(1)**

(1)**

(1)**

(1)**

VRKP4YYYYY00006

Parallel plate with ball pins

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

VRKP4YYYYY00024

Ball pins - set of 12

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

VRKP4YYYYY00025

Ball sockets - set of 12

1

1

1

1

1

1

1

1

1

VRKP4YYYYY00028

Fan

0

0

0

0

(1)***

(1)***

(1)***

(1)***

(1)***

VRKP1YYYYY00032

Springs - set of 6

1

1

1

1

0

0

0

0

0

VRKPXYYYYY00032

0

0

0

0

1

1

1

1

1

VRKP0YYYYY00037

Lower arm pair

1 (2)**

0

0

0

0

0

0

0

0

VRKP1YYYYY00037

0

1 (2)**

1 (2)**

0

0

0

0

0

0

VRKP2YYYYY00037

0

0

0

1 (2)**

1 (2)**

0

0

0

0

VRKP4YYYYY00037

0

0

0

0

0

1 (2)**

0

0

0

VRKP5YYYYY00037

0

0

0

0

0

0

1 (2)**

0

0

VRKP6YYYYY00037

0

0

0

0

0

0

0

1 (2)**

0

VRKP6YYYYY00E37

0

0

0

0

0

0

0

0

1 (2)**

* When using more than one robot, increase the amount accordingly.

** Only if there are increased requirements on the availability of the machine.

*** Only for robots VRKP2•••WD / VRKP4L0•WD / VRKP4L0•NO / VRKP4S0•WF / VRKP5S0•WF / VRKP6S0WF with increased requirements on the availability of the machine.

Replacement Equipment Stock for Robots with a Rotational Axis

When using the Lexium P robots in a production environment, consider keeping the following replacement equipment packages in stock:

Item reference

Item name

Quantity*

VRKP0

VRKP0•••••••E00

VRKP1

VRKP1•••••••E00

VRKP2

VRKP4

VRKP5

VRKP6

VRKP6•••••••E00

VRKP0YYYYY00002

Upper arm

(1)**

(1)**

0

0

0

0

0

0

0

VRKP1YYYYY00002

0

0

(1)**

(1)**

0

0

0

0

0

VRKP2YYYYY00002

0

0

0

0

(1)**

0

0

0

0

VRKP4YYYYY00002

0

0

0

0

0

(1)**

0

0

0

VRKP5YYYYY00002

0

0

0

0

0

0

(1)**

0

0

VRKP6YYYYY00002

0

0

0

0

0

0

0

(1)**

(1)**

VRKP1YYYYY00003

Gearbox main axis

(1)**

(1)**

(1)**

(1)**

0

0

0

0

0

VRKP4YYYYY00003

0

0

0

0

(1)**

(1)**

(1)**

(1)**

(1)**

VRKP4YYYYY00029

Parallel plate with bearing and ball pins

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

VRKP4YYYYY00012

Slide films - three sets of three

1

1

1

1

1

1

1

1

1

VRKP4YYYYY00024

Ball pins - set of 12

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

VRKP4YYYYY00025

Ball sockets - set of 12

1

1

1

1

1

1

1

1

1

VRKP4YYYYY00028

Fan

0

0

0

0

(1)***

(1)***

(1)***

(1)***

(1)***

VRKP1YYYYY00032

Springs - set of 6

1

1

1

0

0

0

0

0

0

VRKPXYYYYY00032

0

0

0

1

1

1

1

1

1

VRKP0YYYYY00033

Telescopic axis

(1)**

0

0

0

0

0

0

0

0

VRKP0YYYYY00E33

0

(1)**

0

0

0

0

0

0

0

VRKP1YYYYY00033

0

0

(1)**

0

0

0

0

0

0

VRKP1YYYYY00E33

0

0

0

(1)**

0

0

0

0

0

VRKP2YYYYY00033

0

0

0

0

(1)**

0

0

0

0

VRKP4YYYYY00033

0

0

0

0

0

(1)**

0

0

0

VRKP5YYYYY00033

0

0

0

0

0

0

(1)**

0

0

VRKP6YYYYY00033

0

0

0

0

0

0

0

(1)**

0

VRKP6YYYYY00E33

0

0

0

0

0

0

0

0

(1)**

VRKP0YYYYY00037

Lower arm pair

1 (2)**

0

0

0

0

0

0

0

0

VRKP1YYYYY00037

0

1 (2)**

1 (2)**

0

0

0

0

0

0

VRKP2YYYYY00037

0

0

0

1 (2)**

1 (2)**

0

0

0

0

VRKP4YYYYY00037

0

0

0

0

0

1 (2)**

0

0

0

VRKP5YYYYY00037

0

0

0

0

0

0

1 (2)**

0

0

VRKP6YYYYY00037

0

0

0

0

0

0

0

1 (2)**

0

VRKP6YYYYY00E37

0

0

0

0

0

0

0

0

1 (2)**

VRKPXYYYYY00040

Plain bearing

1

1

1

1

1

1

1

1

1

VRKPXYYYYY00043

Upper universal joint

1

1

1

1

1

1

1

1

1

VRKPXYYYYY00044

Lower universal joint

1

1

1

1

1

1

1

1

1

* When using more than one robot, increase the quantity accordingly.

** Only if there are increased requirements on the availability of the machine.

*** Only for robots VRKP4L0•WD / VRKP4L0•NO / VRKP4S0•WF / VRKP5S0•WF / VRKP6S0WF with increased requirements on the availability of the machine.

Replacement Equipment Stock for Robots with a Motorized Module

When using the Lexium P robots in a production environment, consider keeping the following replacement equipment packages in stock:

Item reference

Item name

Quantity*

VRKP0

VRKP0•••••••E00

VRKP1

VRKP1•••••••E00

VRKP2

VRKP4

VRKP5

VRKP6

VRKP6•••••••E00

VRKP0YYYYY00002

Upper arm

(1)**

(1)**

0

0

0

0

0

0

0

VRKP1YYYYY00002

0

0

(1)**

(1)**

0

0

0

0

0

VRKP2YYYYY00002

0

0

0

0

(1)**

0

0

0

0

VRKP4YYYYY00002

0

0

0

0

0

(1)**

0

0

0

VRKP5YYYYY00002

0

0

0

0

0

0

(1)**

0

0

VRKP6YYYYY00002

0

0

0

0

0

0

0

(1)**

(1)**

VRKP1YYYYY00003

Gearbox main axis

(1)**

(1)**

(1)**

(1)**

0

0

0

0

0

VRKP4YYYYY00003

0

0

0

0

(1)**

(1)**

(1)**

(1)**

(1)**

VRKP4YYYYY00024

Ball pins - set of 12

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

(1)**

VRKP4YYYYY00025

Ball sockets - set of 12

1

1

1

1

1

1

1

1

1

VRKP4YYYYY00028

Fan

0

0

0

0

(1)***

(1)***

(1)***

(1)***

(1)***

VRKP1YYYYY00032

Springs - set of 6

1

1

1

1

0

0

0

0

0

VRKPXYYYYY00032

0

0

0

0

1

1

1

1

1

VRKP0YYYYY00037

Lower arm pair

1 (2)**

0

0

0

0

0

0

0

0

VRKP1YYYYY00037

0

1 (2)**

1 (2)**

0

0

0

0

0

0

VRKP2YYYYY00037

0

0

0

1 (2)**

1 (2)**

0

0

0

0

VRKP4YYYYY00037

0

0

0

0

0

1 (2)**

0

0

0

VRKP5YYYYY00037

0

0

0

0

0

0

1 (2)**

0

0

VRKP6YYYYY00037

0

0

0

0

0

0

0

1 (2)**

0

VRKP6YYYYY00E37

0

0

0

0

0

0

0

0

1 (2)**

VRKPXYYYYY00045

Rotational Module B

0

0

0

0

0

(1)**

0

0

0

* When using more than one robot, increase the amount accordingly.

** Only if there are increased requirements on the availability of the machine.

*** Only for robots VRKP2•••WD / VRKP4L0•WD / VRKP4L0•NO / VRKP4S0•WF / VRKP5S0•WF / VRKP6S0WF with increased requirements on the availability of the machine.