Refer to Diagnostic class (standard): 3
|
Default reaction |
||
|---|---|---|
|
BD2 |
CD |
|
|
– |
– |
|
|
BD2 |
– |
The cooling element of the PacDrive servo amplifier is too hot.
|
For the motor/drive system: |
|
|---|---|
|
Cause |
Solution |
|
Insufficient ventilation or ambient temperature too high. |
|
|
The power stage or the power rectifier is overloaded. |
|
|
Detected hardware error: The temperature sensor is inoperable. |
Replace the device. |
The temperature of the power stage of the multi carrier segment is too high.
|
For the Multi carrier transport system: |
|
|---|---|
|
Cause |
Solution |
|
Insufficient ventilation or ambient temperature too high. |
Lower the ambient temperature or improve the surface ventilation of the multi carrier segment. |
|
Thermal transition between the multi carrier segment and the mounting plate is not sufficient. |
Improve the thermal transition between the multi carrier segment and the mounting plate (for example, by using thermal paste). |