Replacing the Motor or Gearbox (Optional Equipment)
The use and application of the information contained herein require expertise in the design and programming of automated control systems. Only you, the user, machine builder or integrator, can be aware of all the conditions and factors present during installation and setup, operation, repair, and maintenance of the machine or process.
You must also consider any applicable standards and/or regulations with respect to grounding of all equipment. Verify compliance with any safety information, different electrical requirements, and normative standards that apply to your machine or process in the use of this equipment.
The optional motor or gearbox of the Lexium PAS4•B-Series is coupled by using a preloaded elastomer coupling.
NOTE: Before dismounting, note the mounting orientation of the motor or gearbox to remount the motor or gearbox in the same orientation.
|
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH |
oDisconnect all power from all equipment including connected devices prior to removing any covers or doors, or installing or removing any accessories, hardware, cables, or wires. oPlace a "Do Not Turn On" or equivalent hazard label on all power switches and lock them in the non-energized position. oWait 15 minutes to allow the residual energy of the DC bus capacitors to discharge. oMeasure the voltage on the DC bus with a properly rated voltage sensing device and verify that the voltage is less than 42.4 Vdc. oDo not assume that the DC bus is voltage-free when the DC bus LED is off. oBlock the carriage to prevent rotation prior to performing any type of work on the drive system. oDo not create a short-circuit across the DC bus terminals or the DC bus capacitors. oReplace and secure all covers, accessories, hardware, cables, and wires and confirm that a proper ground connection exists before applying power to the unit. oUse only the specified voltage when operating this equipment and any associated products. |
Failure to follow these instructions will result in death or serious injury. |
|
UNINTENDED MOVEMENTS DUE TO DISMOUNTING |
Secure the moving parts of the axis mounted in a vertical or tilted position against unexpected movements. |
Failure to follow these instructions can result in death, serious injury, or equipment damage. |
You need the following tools to remove the motor or gearbox:
oSet of hex keys
NOTE: Do not use ball head hex keys. Excessive torque may cause the ball head to break away. A broken ball head makes the removal of the screw difficult.
For suitable parts, refer to Replacement Equipment and Accessories.
Perform the following procedures to replace the motor and/or gearbox:
oPreparing the replacement of motor and/or gearbox
oRemoving the motor from the gearbox
Preparing the Replacement of Motor and/or Gearbox
Step |
Action |
---|---|
1 |
Remove or support the payload and the carriage if the axis is tilted or mounted vertically. |
If possible, position the axis such that the top of the carriage points upwards during installation.
NOTE: If the axis is mounted vertically or tilted, secure the carriage to keep it from falling.
Step |
Action |
---|---|
1 |
Remove the cables of the motor (1). ![]()
|
2 |
Secure the motor to keep it from falling and remove the four screws (2) and the washers (3) by means of which the motor is mounted to the motor adapter plate (5). |
3 |
Pull the motor with mounted clamping hub (4) carefully off the motor adapter plate. NOTE: This requires a greater force of up to 450 N (101.16 lbf). |
4 |
Loosen the clamping screw (6) on the clamping hub and withdraw the clamping hub carefully from the motor. ![]()
|
5 |
Mount the new motor as described in Mounting a Motor and Gearbox. NOTE: If the shaft dimensions of the new motor differ from the shaft dimensions of the previous motor, use a new appropriate clamping hub. For further information about appropriate clamping hubs, refer to Replacement Equipment and Accessories. |
If possible, position the axis such that the top of the carriage points upwards during installation.
NOTE: If the axis is mounted vertically or tilted, secure the carriage to keep it from falling.
Step |
Action |
---|---|
1 |
Remove the motor from the gearbox if a motor is mounted. For further information about removing the motor, refer to the corresponding gearbox manual. |
2 |
Secure the gearbox (2) to keep it from falling and remove the four screws (1) by means of which the flange plate (3) is mounted to the motor adapter plate (5). ![]()
|
3 |
Pull the flange plate with mounted gearbox and clamping hub (4) carefully off the motor adapter plate. NOTE: This requires a greater force of up to 450 N (101.16 lbf). |
4 |
Loosen the clamping screw (6) on the clamping hub and withdraw the clamping hub carefully from the gearbox. ![]()
|
5 |
In case the new gearbox does not have its own flange, remove the four screws (7) at the flange plate and then remove the flange plate. ![]()
|
6 |
Mount the new gearbox as described in Mounting a Motor and Gearbox. NOTE: If the shaft dimensions of the new gearbox differ from the shaft dimensions of the previous gearbox, use a new appropriate clamping hub. For further information about appropriate clamping hubs, refer to Replacement Equipment and Accessories. |
Removing the Motor from the Gearbox
For information about removing the motor from the gearbox, refer to the corresponding gearbox manual.