Inout
|
DriveX
|
AXIS_REF_SM3
|
Reference to x-axis.
|
DriveY
|
AXIS_REF_SM3
|
Reference to y-axis.
|
Input
|
dOffsetX
|
LREAL
|
Offset x-position. Equivalent to SMC_TRAFO_Gantry2
|
dOffsetY
|
LREAL
|
Offset y-position. Equivalent to SMC_TRAFO_Gantry2
|
dAlpha
|
LREAL
|
Angle indicating orientation of tool, can be calculated by use of SMC_CalcDirectionFromVector
|
dToolA
|
LREAL
|
Tool size = distance(set position) - (machine position)
|
minX
|
LREAL
|
Lower bound of move range in x-direction(for visualization purpose)
|
maxX
|
LREAL
|
Upper bound of move range in x-direction(for visualization purpose)
|
minY
|
LREAL
|
Lower bound of move range in y-direction(for visualization purpose)
|
maxY
|
LREAL
|
Upper bound of move range in y-direction(for visualization purpose)
|
Output
|
dx
|
LREAL
|
X-position
|
dy
|
LREAL
|
Y-position
|
dnx
|
LREAL
|
Normed x-position (with value in [0,1])
|
dny
|
LREAL
|
Normed y-position (with value in [0,1])
|
dnl
|
LREAL
|
Normed length of the tool
|
ratio
|
LREAL
|
ratio x-interval / y-interval
|
dnOffsetX
|
LREAL
|
X-offset for visualization
|
dnOffsetY
|
LREAL
|