To see the general representation in IL or ST language, refer to the chapter Function and Function Block Representation.
This table describes the input variables:
|
Input |
Type |
Initial Value |
Description |
|---|---|---|---|
|
|
AXIS_REF_PTO |
- |
Name of the axis (instance) for which the function block is to be executed. In the devices tree, the name is declared in the controller configuration. |
|
|
BOOL |
FALSE |
On rising edge, starts the function block execution. On falling edge, resets the outputs of the function block when its execution terminates. |
|
|
INT |
0 |
ID of the requested parameter (PTO_PARAMETER) |
|
|
BOOL |
FALSE |
Value to be written to the requested parameter. |
This table describes the output variables:
|
Output |
Type |
Initial Value |
Description |
|---|---|---|---|
|
|
BOOL |
FALSE |
If TRUE, indicates that the function block execution is finished with no error detected. |
|
|
BOOL |
FALSE |
If TRUE, indicates that an error was detected. Function block execution is finished. |
|
|
PTO_ERROR |
|
When |