TM7BDM16B Presentation

Main Characteristics

The table below provides the main characteristics of the TM7BDM16B block:

Main characteristics

Number of input/output channels

16

Input type

Type 1

Input signal type

Sink

Output type

Transistor, 0.5 A max.

Output signal type

Source

Sensor and actuator connection type

M8, female connector type

Description

The following figure shows the TM7BDM16B block:

G-SE-0006622.2.gif

 

(A)   TM7 bus IN connector

(B)   TM7 bus OUT connector

(C)   24 Vdc power IN connector

(D)   24 Vdc power OUT connector

(1)   Input / Output connectors

(2)   Status LEDs

Connector and Channel Assignments

The table below provides the connector and channel assignments of the TM7BDM16B block. For further information, refer to I/O Configuration Tab:

I/O connectors

I/O status LEDs

Channel types

Channels

1

1

Input / Output

I0 / Q0

2

2

Input / Output

I1 / Q1

3

3

Input / Output

I2 / Q2

4

4

Input / Output

I3 / Q3

5

5

Input / Output

I4 / Q4

6

6

Input / Output

I5 / Q5

7

7

Input / Output

I6 / Q6

8

8

Input / Output

I7 / Q7

9

9

Input / Output

I8 / Q8

10

10

Input / Output

I9 / Q9

11

11

Input / Output

I10 / Q10

12

12

Input / Output

I11 / Q11

13

13

Input / Output

I12 / Q12

14

14

Input / Output

I13 / Q13

15

15

Input / Output

I14 / Q14

16

16

Input / Output

I15 / Q15

Status LEDs

The following figure shows the status LEDs of the TM7BDM16B block:

G-SE-0006623.2.gif

 

(1)   TM7 bus status LEDs, set of two LEDs: 1.1 (green) and 1.2 (red)

(2)   I/O status LEDs, composed of sixteen LEDs (orange)

(3)   I/O block status LEDs, set of two LEDs: 3.1 (green) and 3.2 (red)

The table below provides the TM7 bus status LEDs of the TM7BDM16B block:

TM7 bus status LEDs

Description

LED 1.1

LED 1.2

OFF

OFF

No power supply on TM7 bus

ON

ON

TM7 bus in preoperational state:

opower supply on TM7 bus and

oblock not initialized

ON

OFF

TM7 bus in operational state

OFF

ON

TM7 bus error detected

The table below provides the I/O status LEDs of the TM7BDM16B block:

Channel LEDs

State

Description

1 to 16

OFF

Corresponding input/output deactivated

1 to 16

ON

Corresponding input/output activated

The table below provides the I/O block status LEDs of the TM7BDM16B block:

Block status LEDs

State

Description

3.1

OFF

No power supply

Single Flash

Reset state

Flashing

Preoperational state

ON

Operational state

3.2

OFF

OK or no power supply

Single Flash

Detected error for an I/O channel:

oDI: Overflow or underflow of the input signal

oDO: Overcurrent or short circuit

Double Flash

Power supply not in the valid range

ON

Detected error or reset state