Introduction to the IEC 60870-5 KEMA Driver

This driver is an extension driver. It provides additional application-specific functionality to the 'parent' driver with which it is associated. To interact successfully with devices using an extension driver, you need to:

Intended Audience

This guide is intended for engineers who are responsible for configuring IEC 60870-5 KEMA items and features in the Geo SCADA Expert database.

Document Scope

This guide explains the configuration, features and database items that are specific to Geo SCADA Expert's IEC 60870-5 KEMA driver.

The IEC 60870-5 KEMA driver is an IEC 60870-5 extension driver. It provides additional functionality to enable Geo SCADA Expert to communicate specifically with KEMA compliant devices, using the IEC 60870-5-101 protocol over a direct, PSTN or GSM connection. In order to communicate with such devices, your Geo SCADA Expert system needs to be running both the IEC 60870-5 driver and the IEC 60870-5 KEMA extension driver (see Confirm that the Required Geo SCADA Expert Components are Installed).

To enable KEMA compliant devices to communicate with Geo SCADA Expert using the IEC 60870-5-101 protocol over PSTN, the devices need to run suitable logic programs or the relevant part of the device's core firmware/software functionality.

Use this driver guide alongside the Geo SCADA Expert Guide to the IEC 60870-5 Driver. As much of the information in the IEC 60870-5 driver guide is assumed knowledge, we recommend that you read the Geo SCADA Expert Guide to the IEC 60870-5 Driver before reading this driver guide. When configuring KEMA compliant devices in Geo SCADA Expert, you might also find it useful to have access to the interoperability Profile documents for both Geo SCADA Expert and the KEMA compliant devices.

This Geo SCADA Expert Guide to the IEC 60870-5 KEMA Driver explains the Terminology of which you need to be aware, and provides detailed information on Configuring IEC 60870-5 KEMA Compliant Devices in Geo SCADA Expert.

For IEC 60870-5 specific aspects that are not covered in this guide,see the Geo SCADA Expert Guide to the IEC 60870-5 Driver.

Policy of Continuous Development

To maintain Geo SCADA Expert's position as a leading SCADA solution, we operate a policy of continuous development. Each new version of our product supports additional features and functionality to previous releases. To use the new drivers, features, or functionality involving database items, your system has to be running the latest version of Geo SCADA Expert software. Additionally, if you have upgraded from an earlier version of the product, you have to deactivate any Database Emulation that was activated during the upgrade process. You should only deactivate the Database Emulation once you have successfully completed the upgrade process on all of the servers and clients in your system (see Deactivate Database Emulation after a Successful Upgrade).