Fetch and Write

Fetch/Write is a protocol to communicate with a Siemens PLC. If you are using a Siemens 1200 or 1500 series PLC, you will need to grant EcoStruxure Machine Expert Twin full access through TIA.

Properties for Fetch

  • Identification
    • Name – Customizable name
    • Id – Customizable Id
  • Communication
    • Port – Port used for communication between EcoStruxure Machine Expert Twin and “Device”
    • IP Address – Type in IP address (only available if Mode = Client)
    • Mode – Select “Server” or “Client”
    • Source – Choose the data area to be read from. Options are Flag Area(M), Input(I), Output(Q), Data Block(DB), Counter Cells(C) or Timer Cells(T)
    • Update Interval – Measured in milliseconds. Less than 25ms activates fast mode updating
    • Auto Connect – Activate or Deactivate whether EcoStruxure Machine Expert Twin should try to automatically connect to the “Device”
  • Memory Allocation
    • Automatic – Activate or Deactivate automatic memory allocation
    • Length – Set data length (only available if Automatic = False)
    • Offset – Set offset for data (only available if Automatic = False)

Properties for Write

  • Identification
    • Name – Customizable name
    • Id – Customizable Id
  • Communication
    • Port – Port used for communication between EcoStruxure Machine Expert Twin and “Device”
    • IP Address – Type in IP address (only available if Mode = Client)
    • Mode – Select “Server” or “Client”
    • Destination – Choose the data area to be written to. Options are Flag Area(M), Input(I), Output(Q), Data Block(DB), Counter Cells(C) or Timer Cells(T)
    • Synchronized – Activate and Deactivate synchronization
    • Auto Connect – Activate or Deactivate whether EcoStruxure Machine Expert Twin should try to automatically connect to the “Device”
  • Memory Allocation
    • Automatic – Activate or Deactivate automatic memory allocation
    • Length – Set data length (only available if Automatic = False)
    • Offset – Set offset for data (only available if Automatic = False)
Previous Allow Siemens PLC (1200/1500) to communicate with Machine Expert Twin through TIA