Capturing
VisuFbCapturedTransformationProvider (FunctionBlock)
GetTransformation (Method)
SetContent (Method)
VisuFbLegacyCapturingTransformationProvider (FunctionBlock)
SetClient (Method)
Clienthandling
Client Tags
VisuFbClientTagDataHelper (FunctionBlock)
VisuFctFreeClientTagData (Function)
Main Clienthandling
Private
prvGetTags (Function)
VisuFbMainClientMgmt (FunctionBlock)
Manage (Method)
VisuFctMainClientsCheck (Function)
VisuFctMainClientsCheck3 (Function)
VisuFctMainClientsCheckOld (Function)
VisuIsValidClientId (Function)
Visu_ClientMgmt_Constants (GVL)
VisuFbClientStartVisuMgr (FunctionBlock)
GetStartVisu (Method)
Visu_FctReleaseNonIECMemClientResources (Function)
Collections
VisuFbCommandVector (FunctionBlock)
AddEntry (Method)
GetEntryPointer (Method)
Overrides-and-Implementations
abstrAssign (Method)
abstrDataPtrChanged (Method)
abstrSizeOfElement (Method)
Visu_FbStringDintMap (FunctionBlock)
AddOrOverwrite (Method)
Visu_StructCommandData (Struct)
Colors
VisuFctIsTransparentBackground (Function)
VisuFctSplitColor (Function)
Date and Time
Access to Systime library
VisuFctConvertUtcToSystimedate (Function)
VisuFctGetNanosSince1970 (Function)
Recent
IDateTimeLanguageTextTarget (Folder)
AssignLanguageText (Method)
VisuDateTimeFormatPlaceholders (Enum)
VisuFbAnalyzeDateTimeFormatExtractWithoutWeekdays (FunctionBlock)
Abstract-methods
EndFormatPart (Method)
StartFormatPart (Method)
GetFormat (Method)
Initialize (Method)
VisuFbAnalyzeDateTimeFormatStringBase (FunctionBlock)
CharFound (Method)
PlaceholderFound (Method)
Analyze (Method)
CheckCandidateForDecimals (Method)
GetCharHelp (Method)
GetLanguageText (Method)
GetLanguageTextMayShort (Method)
InitFormat (Method)
Private-Methods
GreedilyHandleSameChars (Method)
VisuFbAnalyzeDateTimeFormatStringMinSecOnly (FunctionBlock)
CheckMinuteSecondUsage (Method)
Overrides
VisuFbPrintDateTimeFormatBase (FunctionBlock)
FormatToGlobalTextBuffer (Method)
IDateTimeLanguageTextTarget
VisuFbPrintDateTimeFormatCurrentTime (FunctionBlock)
InitializeWithSysTimeDate (Method)
VisuFbPrintDateTimeFormatVariable (FunctionBlock)
VisuFbWriteDateTimeVariableFormatted (FunctionBlock)
AssignIfValid (Method)
AssignIfValidConvertible (Method)
GetStructTimeDate (Method)
ValidateAgainstInputChecks (Method)
VisuFbDateTimeNamesLocalizer (FunctionBlock)
CopyLanguageText (Method)
GetDayLong (Method)
GetDayShort (Method)
GetMonthLong (Method)
GetMonthShort (Method)
Dialog Management
Position infos
VisuFbDialogPos (FunctionBlock)
FB_Exit (Method)
VisuFbDialogPosByElementVector (FunctionBlock)
VisuFbDialogPosVector (FunctionBlock)
VisuStructDialogPosByElement (Struct)
Structures
VisuStructAllDialogInfo (Struct)
VisuStructAllModalDialogInfo (Struct)
VisuStructAllNonModalDialogInfo (Struct)
VisuDialogOpenFlags (Enum)
VisuFbDialogClientInfo (FunctionBlock)
FB_Init (Method)
Version (Property)
VisuFbDialogInfoVector (FunctionBlock)
Visu_FctSetDialogClientData (Function)
ElementSearch
VisuFctSearchElementById (Function)
Event Handling
EventQueueAndElement (Struct)
EventQueuePerClient
EventElementData (FunctionBlock)
GVL_Events (GVL)
VisuFctAddClientToEventQueue (Function)
VisuFctCreateEventMapIfNeeded (Function)
VisuFctRemoveClientFromEventQueue (Function)
LegacyRTSVisuStructEvent2 (Struct)
VisuFctHandleInputOnElementEvent (Function)
Visu_FbClearEventsAfterStart (FunctionBlock)
EventCallback (Method)
Init (Method)
Visu_FctLegacyIDStackInfoFill (Function)
Visu_FctLegacyIDStackInfoReadFromAdditionalData (Function)
File transfer
VisuEnumFileTransferDirection (Enum)
VisuEnumFileTransferInputEventType (Enum)
VisuFbFileTransferManager (FunctionBlock)
GetParamForFileTransf (Method)
GetParamForStreamTransf (Method)
GetStringBuffer (Method)
NormalizeFilePath (Method)
RequestStreamingPlcToVisu (Method)
RequestStreamingVisuToPlc (Method)
RequestStreamingVisuToPlc2 (Method)
RequestTransfer (Method)
RequestTransfer2 (Method)
RequestTransfer3 (Method)
internal
ClientRemoved (Method)
ReadFileName (Method)
VisuStructFileTransfParams_Union (Union)
Frame Switching
VisuFbFrameRegistrationVector (FunctionBlock)
GetIndexByPath (Method)
FramePreview
Visu_FctGetInitFramePreviewFlags (Function)
GVL_DebugChecks (GVL)
Geometrics
VisuFbPaintRectF (FunctionBlock)
AsPaintRectStruct (Method)
FromPointAndSize (Method)
RotateBy (Method)
VisuFbPointF (FunctionBlock)
AsPointStruct (Method)
AsPointStructI (Method)
AsSize (Method)
Checksum (Method)
FromEventDwordParam (Method)
FromPointStruct (Method)
FromPointStructI (Method)
FromRectangleStructLocation (Method)
FromWidthHeight (Method)
MoveBy (Method)
MoveByComponents (Method)
MoveByNonRef (Method)
MovedCopy (Method)
RotatedCopy (Method)
ScaledCopy (Method)
Subtract (Method)
SubtractBy (Method)
ToEventDwordParam (Method)
TransformOverlay (Method)
VisuFbRectF (FunctionBlock)
Center (Method)
FromRect (Method)
ResizeBy (Method)
Size (Property)
VisuFbSizeF (FunctionBlock)
AsPoint (Method)
FromPoint (Method)
FromRectangleStruct (Method)
IncrementBy (Method)
IncrementByComponents (Method)
IncrementedCopy (Method)
MultiplyByComponents (Method)
Negate (Method)
SubtractByNonRef (Method)
SubtractedCopy (Method)
Transform (Method)
Untransform (Method)
Gestures
VisuFbGestureFromEvent (FunctionBlock)
FillFlick (Method)
FillIECTouchInfo (Method)
FillPan (Method)
FillResult (Method)
FillSpreadPinch (Method)
UntransformOffset (Method)
VisuGestureInfo (Union)
VisuStructFlickInfo (Struct)
VisuStructIECTouchInfo (Struct)
VisuStructPanInfo (Struct)
VisuStructSpreadPinchInfo (Struct)
Visu_FctIsGestureEvent (Function)
Visu_FctIsRelevantGestureEvent (Function)
Input Event Handling
Visu_FctRaiseMouseLeave (Function)
Inputs
HandleVisuInput
Visu_FctClosePAADialogIfNecessary (Function)
Visu_FctHandleVisuInputDialogTarget (Function)
Visu_FctHandleVisuInputMouseEvent (Function)
Visu_FctHandleVisuInputOverlayMeasureString (Function)
Visu_FctHandleVisuInputPAA (Function)
VisuFbMouseTouchDragUtil (FunctionBlock)
HandleMouseEvent (Method)
private
prvIsRelevantEvent (Method)
VisuFctClearEventIdStack (Function)
VisuFctCreateIdStack (Function)
VisuFctEventIdStackGetValue (Function)
VisuFctEventIdStackGetValuePtr (Function)
VisuFctEventIdStackGetValuePtrFromEvent2 (Function)
VisuFctEventIdStackGetValuePtrFromEventLegacy (Function)
VisuFctEventIdStackHas (Function)
VisuFctEventIdStackPopHelp (Function)
VisuFctEventIdStackPopId (Function)
VisuFctEventIdStackPopTarget (Function)
VisuFctEventIdStackPopVisuVersion (Function)
VisuFctEventIdStackPushId (Function)
VisuFctEventIdStackSetValue (Function)
VisuFctSetSelectionChanged (Function)
Visu_FctHandleInputGesture (Function)
Visu_FctIsEventToIgnoreWhileEditboxOpen (Function)
Visu_FctIsModalDialogOpen (Function)
Namespaces Table
VisuFbLibHierarchy (FunctionBlock)
VisuFbNamespaceTable (FunctionBlock)
Dump (Method)
VisuStructNamespace (Struct)
VisuStructNamespaceProjectIdent (Struct)
Visu_HelpDumpLibHierarchy (Function)
Native Control
VisuFbNativeControlItemVector (FunctionBlock)
AddItem (Method)
GetItemPointer (Method)
NativeElement
ArrayRangeHelper (FunctionBlock)
AddByteArray (Method)
GetSize (Method)
OnlineChange
Visu_OnlinechangeNotify (Function)
Visu_SetCodegenFeatureSupport (Function)
PaintAfterAllDialog
VisuFbPaintAfterAllDialog (FunctionBlock)
ClosePAADialog (Method)
ClosePAADialog2 (Method)
CollectRectangles (Method)
EndPaintAfterAllDialog (Method)
GetElementArray (Method)
GetSurroundingRect (Method)
GetUpdateRects (Method)
HandleInput (Method)
HandlePAASelection (Method)
InitializePAADialog (Method)
OwningElement (Property)
Paint (Method)
SetCallbackTarget (Method)
SetClientData (Method)
SetTransformPAA (Method)
StartPaintAfterAllDialog (Method)
StartPaintAfterAllDialog2 (Method)
Unnecessary-functions
ContainsPoint (Method)
Destruct (Method)
ElementInfo (Method)
GetClientData (Method)
GetDialogInterface (Method)
GetDialogInterfaceSize (Method)
GetElementIdArray (Method)
GetInstance (Method)
GetName (Method)
GetNamespace (Method)
GetResult (Method)
GetText (Method)
GetTextProperties (Method)
GetTooltip (Method)
GetTranslator (Method)
SetDialogInterface (Method)
SetResult (Method)
SetStaticState (Method)
SetVisuFlagsInternal (Method)
Update (Method)
prvSetFlags (Method)
VisuFctExitVisuClientObject (Function)
VisuFctHandleInputVisuClientObject (Function)
VisuFctInitFlagsVisuClientObject (Function)
VisuFctInitVisuClientObject (Function)
VisuFctPaintVisuClientObject (Function)
VisuFctSetClientDataVisuClientObject (Function)
PropertySupport
Visu_CheckPropertyInfo (Function)
Visu_ScalarTypesUnion (Union)
Visu_ScalarTypesWithPtr (Struct)
Selection Management
IPaintSelectionInElement (Interface)
DrawingOffset (Property)
FrameSize (Property)
VisuFctIsToPaintSelection (Function)
Visu_FctIsOnStraightLine (Function)
Visu_FctIsSelectionEmpty (Function)
Visu_FctTransformSelectionIsotropicOverlay (Function)
StringFunctions
Visu_FctCheckForLongFormatSpecifier (Function)
Styles
VisuStyleFct_GetImageAccordingMapping (Function)
Transformation
VisuFbTransformationCommon (FunctionBlock)
ITransformation2
TransformPaintRectangleInOutF (Method)
TransformPointInOutF (Method)
TransformPolygonF (Method)
ITransformation3
TransformPointInOutOverlay (Method)
TransformPointInOutOverlayF (Method)
SetOffset (Method)
SetScaleValues (Method)
SetTransformationValues (Method)
SetTransformationValuesWithClientObjectPositions (Method)
TransformFontSize (Method)
TransformHeight (Method)
TransformPaintRectangle (Method)
TransformPaintRectangleInOut (Method)
TransformPoint (Method)
TransformPointInOut (Method)
TransformPolygon (Method)
TransformWidth (Method)
TransformYCoordinate (Method)
UntransformHeight (Method)
UntransformPoint (Method)
UntransformWidth (Method)
VisuFbTransformationScrolling (FunctionBlock)
TypeInformation
SetValueOfTypeDesc (Function)
User Events
VisuStructInputOnElementEvent (Struct)
Visu Element Management
ClientObjectInfo
IQueryInterfaceElement (Interface)
GetQueryInterface (Method)
VisuFctGetAbsolutePosition (Function)
IVisualElementWithoutBlobInit (Interface)
GetPosition (Method)
ModifyPosition (Method)
VisuClientAnimationData (Struct)
VisuClientObject (FunctionBlock)
CheckVisibilityTransition (Method)
GetElement (Method)
GetMaximalElementCount (Method)
ILayerManager
EndLayer (Method)
SetAdditionalLayers (Method)
StartLayer (Method)
IResizeHandler
HandleResize (Method)
HasAnimation (Method)
SetResize (Method)
TryHandleInputDirectly (Method)
AdjustPaintFlagsForContainer (Method)
setCurrentPosition (Method)
VisuClientObjectClientSpecificData (Struct)
VisuClientObjectFlags (Enum)
VisuClientObjectFlags_HighWord (Enum)
VisuClientObjectIdStack (FunctionBlock)
AddClientObjectEndIdStack (Method)
AddClientObjectStartIdStack (Method)
Clear (Method)
PopId (Method)
PushId (Method)
RestoreFrom (Method)
VisuClientObjectIdStackOptimized (FunctionBlock)
AddClientObjectEndToStack (Method)
AddClientObjectStartToStack (Method)
AddDanglingClientObjectCommands (Method)
IsEmpty (Method)
VisuClientObjectIdStackWithParentSize (FunctionBlock)
VisuClientObjectInputRectangleMgr (FunctionBlock)
MouseDownHandling (Property)
SetInputRectangleList (Method)
VisuClientObjectLayerInitFlags (Enum)
VisuClientObjectMgr (FunctionBlock)
BlobInit (Method)
PaintWithBackground (Method)
SetElemIndexParent (Method)
SetNextElementIndex (Method)
VisuClientObjectReservedIds (Enum)
VisuClientObjectStateFlags (Enum)
VisuElemLayer
VisuElemLayer (FunctionBlock)
AdditionalHeight (Property)
AdditionalWidth (Property)
Alignment (Property)
ClippingActive (Property)
ClippingRect (Property)
GetInitFlag (Method)
Height (Property)
Id (Property)
Initialized (Property)
ScrollableX (Property)
ScrollableY (Property)
Width (Property)
X (Property)
Y (Property)
VisuElemLayerAlignmentFlag (Enum)
VisuElemLayerClientSpecificData (Struct)
VisuElemLayerData (Struct)
VisuElemLayerFlag (Enum)
VisuElemSelectionLayer (FunctionBlock)
PreventLegacyPositionAdaption (Method)
UpdatePosition (Method)
VisuElemMgrClientData (Struct)
VisuElemMgrClientSpecificData (Struct)
VisuElemMgrClientSpecificDataIndices (Struct)
VisuScrollValueData (FunctionBlock)
VisuScrollValueProvider (FunctionBlock)
CurrentValueX (Property)
CurrentValueY (Property)
SetLimitsX (Method)
SetLimitsY (Method)
Visu Execution
VisuFbExecution (FunctionBlock)
CallPaint (Method)
CallUpdate (Method)
CanUpdate (Method)
EndCycle (Method)
Execute (Method)
ExecuteInputsHelp (Method)
ExecuteInputsHelpDo (Method)
ExecuteNotificationsAfterInvalidateIfNecessary (Method)
ExecuteNotificationsIfNecessary (Method)
ExecuteSingleInputEvent (Method)
ExtractAndExecuteTouchToMouseEvents (Method)
IsEventTypeForOptimization (Method)
PopTransformation (Method)
PopTransformationRespectBestFit (Method)
prvCollectRectanglesIfNecessary (Method)
prvFillMouseFromTouch (Method)
PushTransformation (Method)
PushTransformationRespectBestFit (Method)
SetConfigAutoFontSizeReduction (Method)
SetIgnoreVisuPaint (Method)
StartCycle (Method)
VisuFctDrawIsoBackground (Function)
Visu Management
VisuFbVisuVector (FunctionBlock)
AddVisualization (Method)
GetVisualization (Method)
GetVisualizationIndex (Method)
RemoveVisualization (Method)
SwapEntries (Method)
Visu Scaling
Touch Handling
VisuFbRectangleListManager (FunctionBlock)
AddLargeScrollLimits (Method)
IRectangleListManager
AddRectangle (Method)
AddZoomScrollLimits (Method)
ForwardCall (Method)
ForwardCallWithMouseDownInfo (Method)
PopClipping (Method)
PushClipping (Method)
SetUpdateNecessary (Method)
IRectangleListManager2
AddContentRect (Method)
AddRectangleTransformed (Method)
AddTouchRectRenderLocationInfo (Method)
PushClippingTransformed (Method)
IRectangleListManager3
AddContentRectTransformed (Method)
IsUpdateNecessary (Property)
DoAddScrollLimits (Method)
DoAddZoomLimits (Method)
VisuFctGetTargetVisuTouchFlags (Function)
VisuFbScalingInfo (FunctionBlock)
IsChanged (Method)
Reset (Method)
UpdateFromGestureHelper (Method)
VisuStructScaleScrollInfo (Struct)
VisuEventOptimization (FunctionBlock)
AssignEvent (Method)
CanBeHandledWihtoutPainting (Method)
IsSameMouseMoveEvent (Method)
VisuFbBaseVector (FunctionBlock)
InitStaticMemory (Method)
RemoveEntryAt (Method)
VisuFbClientLogger (FunctionBlock)
WriteMessageInBuffer (Method)
VisuFbDWORDVector (FunctionBlock)
AddDWORD (Method)
GetDWORD (Method)
VisuFbInputRectangle (FunctionBlock)
Bottom (Property)
Flags (Property)
Left (Property)
Right (Property)
Top (Property)
VisuFbNamespaceTableHelper (FunctionBlock)
GetNextAccessPath (Method)
SetInitAccessPath (Method)
prvDeriveNamespaceFromAccessPath (Method)
prvFindInitialNamespaceIndex (Method)
VisuFbPaintAfterAllElement (FunctionBlock)
GetAdditionalClientDataSize (Method)
ICapturingElement
IsCapturingEventsActive (Property)
IInputRectangleProvider
ProvideInputRectangleList (Method)
ILayeredVisualElement
SetLayerManager (Method)
IMultitouchElement
GetScrollValueProvider (Method)
IsMultitouchElementActive (Method)
OnScrollValueChanged (Method)
IRectangleProvider
AddRectangles (Method)
IVisualElement3
GetCompleteSurroundingRect (Method)
VisuFbTemporaryPolygon (FunctionBlock)
Copy (Method)
CopyToF (Method)
VisuFbValueChangedListenerForOnValueChanged (FunctionBlock)
ValueChanged (Method)
VisuFctAssignValue (Function)
VisuFctCheckSpecificClientType (Function)
VisuFctClearElementEntries (Function)
VisuFctGetEffectiveTextProperties (Function)
VisuFctGetElementState (Function)
VisuFctGetLineJoinMiterLimit (Function)
VisuFctIncreaseCurrentElementIndex (Function)
VisuFctIsMultitouchClient (Function)
VisuFctRectSize (Function)
VisuFctSetNumericValue (Function)
VisuFctSetRectangleUpdateNecessaryOnAllClients (Function)
VisuFctTextAddOffset (Function)
VisuFctTryAtomicAssignValueBySize (Function)
VisuFctTryAtomicAssignValueByType (Function)
VisuFctWriteValueIfValid (Function)
VisuFct_IsBehindOverlayElement (Function)
VisuRegistrationHelpDuringDecl (Function)
VisuSecureTappingKeyEvent (FunctionBlock)
DoSecureTapping (Method)
Visu_Assert (Function)
Visu_FctGetDevicePixelRatioFromAdditionalData (Function)
Visu_FctInitMemSet (Function)
Webvisu
Visu_FbWebserver (FunctionBlock)
OpenIfNecessary (Method)