Libraries:
The GMC Independent PLCopen MC library
Library name: GMC Independent PLCopen MC
Namespace: GIPLC
The GMC Independent Altivar library
Library name: GMC Independent Altivar
Namespace: GIATV
The GMC Independent Lexium library
Library name: GMC Independent Lexium
Namespace: GILXM
Naming conventions:
Function blocks with the prefix MC_ (Motion Control) are compliant with the PLCopen specification V2.00. They conform to a global standard for programming motion control applications.
Function blocks without a prefix MC_ are vendor-specific (Schneider Electric); however, they comply with the general PLCopen rules.
Drive |
CANopen |
EtherNet/IP |
Modbus TCP |
---|---|---|---|
ATV320, ATV340, ATV6••, ATV9••, LXM32M, Lexium ILA, ILE and ILS |
✓ |
✓ |
✓ |
LXM32A, LXM32ICAN, SD328A |
✓ |
- |
- |
✓ Supported - Not supported |
The GMC Independent PLCopen MC library contains these function blocks that can be used with Altivar, Lexium 32, Lexium SD328A and Lexium ILA, ILE and ILS integrated drives:
Category |
Function block |
Description |
---|---|---|
Single axis |
Initialization |
|
Operating mode: Jog |
||
Operating mode: Profile Torque |
||
Operating mode: Profile Velocity |
||
Operating mode: Profile Position |
||
Operating mode: Homing |
||
Stopping |
||
Position capture via signal input |
||
Administrative |
Reading a parameter |
|
Writing a parameter |
||
Inputs and outputs |
||
Error handling |
||
The GMC Independent Altivar library contains these function blocks that can be used with Altivar drives:
Category |
Function block |
Description |
---|---|---|
Single axis |
Operating mode: Profile Velocity |
|
Administrative |
Writing a parameter |
|
Inputs and outputs |
The GMC Independent Lexium library contains function blocks that can be used with Lexium drives.
These function blocks can be used with Lexium 32 drives:
Category |
Function block |
Description |
---|---|---|
Single axis |
Operating mode: Jog |
|
Operating mode: Profile Torque |
||
Operating mode: Profile Velocity |
||
Operating mode: Homing |
||
Stopping |
||
Position capture via signal input |
||
Multi axis |
Operating mode: Electronic Gear |
|
Administrative |
Writing a parameter |
|
Error handling |
These function blocks can be used with Lexium SD328A drives:
Category |
Function block |
Description |
---|---|---|
Single axis |
Operating mode: Jog |
|
Operating mode: Profile Velocity |
||
Operating mode: Homing |
||
Position capture via signal input |
||
Multi axis |
Operating mode: Electronic Gear |
|
Administrative |
Writing a parameter |
|
These function blocks can be used with Lexium ILA, ILE and ILS integrated drives:
Category |
Function block |
Description |
---|---|---|
Single axis |
Operating mode: Jog |
|
Operating mode: Homing |
||
Stopping |
||
Position capture via signal input |
||
Operating mode: Speed Control |
||
Multi axis |
Operating mode: Electronic Gear |
|
Administrative |
Writing a parameter |
|
Error handling |